    • The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection graphic keypad support and dual partitions. The panel's installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.
Features:
    • Eight on-board hard-wire zones standard (15 when Zone Doubling feature is used)
    • Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
    • Supports 6270 graphic touchscreen keypads
    • Wireless keys can be programmed without using zones
    • 16 output devices: Relays (Model 4204 Relay Modules, or 4229 Expansion Module)
    • Two low current on-board trigger outputs
    • 100 Event Log viewable at system keypads with time/date stamp
    • 48 system user codes assignable to either partition
    • Two independent partitions plus a common partition
      • Global Arming from any system keypad
      • Goto function to view or operate one partition from the other
      • Separate partition account numbers
    • Four installer configurable zone types allows the installer to create custom zone types by assigning all zone attributes
    • Multiple actions on output devices depending on system "state"
      • Turns lights off when system arms
      • Turns the same light on when system disarms
      • Flashes same lights when system is in alarm
    • Built-in phone line cut monitor with programmable delay and annunciation options
      • Display on system keypads
      • Trigger local sounders
      • Trigger system bell
    • Supports four-wire, and up to 16 two-wire smokes
      • Works with Sentrol CleanMe™ maintenance signal
    • Valuable End User Features
      • Now viewable on system keypads:
        • Exit countdown
        • Time and date display*
        • Event log*
      • Auto keypad back-lighting on entry
      • Key-switch arming
      • Programmable macro buttons and single-button arming
      • A variety of wireless remote controls for single-button operation
      • User Scheduling
        • Automatically activates relays at programmed times
        • Latchkey reports to pagers
        • Auto arm/disarm
        • "User access" time windows
      • Supports up to four end user numeric pagers
      • VIP Module allows system control from any touch-tone phone
      • Chime by zone
    • Security Dealer Features
      • Automatic System Load Shed: During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
      • Dynamic Signaling: Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and Alarm-Net radio
    • Requires custom alpha keypad
Specifications:
    • Electrical:
      • Aux. power 12V DC, 600mA maximum
      • Seven hour standby at 400mA aux. load with four amp hour battery
      • 16.5V AC/25VA transformer
      • Alarm output 12V DC, 2.0 amps maximum
      • For UL installations, combined aux. and alarm output cannot exceed 700mA
    • Output Control:
      • Supports up to four relay boards (up to 16 relays)
    • Zones:
      • Eight hardwired zones (15 with zone doubling)
      • Selectable response 10msec, 350msec, 750msec
      • Assignable to any partition
      • 20 selectable zone types plus four configurable zone types
      • Programmable swinger suppression
    • Expansion Devices:
      • 4219 - Eight hardwired zones - 16mA
      • 4204 - Up to four relays - 15mA standby (each active relay draws an additional 40mA)
      • 4229 - Eight hardwired zones and two relays - 36mA (each active relay draws an additional 40mA)
    • Accessories:
      • 4286 VIP Voice Module - 220mA
      • 5881ENH RF Receiver support up to 40 zones - 50mA
      • 5883 Transceiver supports up to 40 zones - 80mA
      • Supports Eagle 1225 and 1221 boards
    • Keypads:
      • 6160 Custom Alpha (required for programming) - 100mA
      • 6150RF Fixed English RF LCD 85mA/40mA
      • 6148 Fixed English LCD - 70mA/30mA
      • 6270 Graphic touchscreen user interface
    • Agency Listings:
      • UL Residential Fire, Burglary and CSFM
    • Smoke Detectors:
      • Supports up to 16 two-wire smoke detectors
      • Supports four-wire smoke detectors
    • Communications:
      • Touch-tone or pulse
      • Formats supported
        • ADEMCO Contact ID
        • ADEMCO 4 + 2 Express
        • ADEMCO low speed
        • Sescoa/Radionics
      • 3 + 1, 4 + 1 and 4 + 2 reporting
      • Reporting capabilities
        • Split
        • Dual
        • Split/Dual - True dial tone detection
      • Low battery reports 11.2 - 11.6V DC
      • AC loss and restore reporting supported


*Prices are subject to change in accordance to exchange rate

Add Vista-20P to del.icio.us Add Vista-20P to Digg Add Vista-20P to Ekstreme Add Vista-20P to Facebook Add Vista-20P to Furl Add Vista-20P to Google Add Vista-20P to Newsvine Add Vista-20P to Reddit Add Vista-20P to Technorati Add Vista-20P to Twitter Add Vista-20P to Yahoo myWeb
Related Products
Related Categories
Currently viewing:  VISTA-20P ADEMCO HONEYWELL Alarm Kit
Contact Us
Advertisement
Featured Security Brands

LILIN
NEC
D-Link
PANASONIC
CAPTURE
ADVISION
INTELLISENSE
ZAVIO
OPTEX
YOKO
ADISYS
SAMSUNG
FBII
HONEYWELL
HIKVISION
DAHUA
AVTECH

Home | About us | Contact us | Sitemap | Resources | Relatedsites | Return Policy | Privacy Policy | Terms and Conditions
SecurityIndia.in, Security Products Market Place. Coypright PROLYTICS Software Pvt. Ltd. All Right Reserved© 2012
Comprehensive Guide for Security and Automation Industry